Common_Problems
Common problem and solution of automatic mechanical glass loading table
发布时间:2015-05-18
No.
Common faults
Reason and solution
1
Transmission does not turn, line speed does not display exactly.
(1)drive motor burn out, repair or replace motor
(2) main drive reducer is broken, repair or replace reducer
(3)drive gear or chain is damaged, replace gear or chain
(4) frequency inverter is damaged, repair or replace frequency inverter
(5)  rotary encoder is broken, replace rotary encoder
(6)  digital display is broken or need recalibrate, replace digital display
2
Overturn arm does not operate smoothly
(1) the switch is not in the right position, reset the switch position
(2) frequency inverter acceleration and deceleration parameters is not suitable, adjust according to the frequency inverter instructions
(3)  reducer is broken, repair or replace reducer
(4)  transmission gear is broken, replace the transmission gear
(5)  the first speed and second speed is not suitable, adjust according to frequency inverter instructions
3
Walking suction
Sucker suction is not enough
(1) vacuum electromagnetic valve is damaged, replace the vacuum electromagnetic valve
(2) vacuum gas way is leaked, check vacuum gas way
(3) sucker is broken, replace sucker
(4) vacuum pump is broken, repair or replace vacuum pump
4
Transmission rubber ring is aging and worn
Replace the transmission rubber ring